Question 730
At Bluehaven Transit, an architecture review of transit signalling and rider services across depots and urban transport gateways is underway as part of a resilience design review (DES-2-25-1). The review is led by the transit infrastructure team. The documented design gap: an SD-WAN fabric places high-security and guest networks in one unrestricted overlay policy despite separate business requirements. The solution must proceed with observable, reversible control-plane changes. Which ongoing architecture control best reduces recurrence of this gap?
Explanation
Correct Answer
The ongoing design assurance control is: Run intersegment positive and negative reachability tests after central policy revisions. It is targeted at the documented risk: an SD-WAN fabric places high-security and guest networks in one unrestricted overlay policy despite separate business requirements. The immediate design change is: Implement distinct routing VPN segments with explicit intersegment service controls. In subsequent reviews, validate recurrence prevention with: Unauthorized guest-to-regulated paths fail while approved shared services remain reachable. Applied here, the relevant facts are: networks in one unrestricted overlay policy despite separate business requirements. The solution must proceed with observable, reversible control-plane changes.
Incorrect Answers
This safeguard maintains a different technical control: The ongoing design assurance control is: Review stretched subnet inventory and endpoint mobility requirements quarterly. The recurring risk here is governed by: The ongoing design assurance control is: Run intersegment positive and negative reachability tests after central policy revisions. The relevant review is “Run intersegment positive and negative reachability tests after central policy revisions”.
“Monitor underlay path health separately from overlay tunnel state” is a sensible check for: The ongoing design assurance control is: Monitor underlay path health separately from overlay tunnel state. It is not the prevention measure for the current dependency: The ongoing design assurance control is: Run intersegment positive and negative reachability tests after central policy revisions. The closer guardrail is “Run intersegment positive and negative reachability tests after central policy revisions”.
The alternate safeguard protects a separate dependency: The ongoing design assurance control is: Correlate optics trends with maintenance events and link utilization. For this failure the continuing exposure is: The ongoing design assurance control is: Run intersegment positive and negative reachability tests after central policy revisions. Maintain “Run intersegment positive and negative reachability tests after central policy revisions” instead.