Question 960
At Yardley Airlines, an architecture review of fleet maintenance and scheduling across operational data centers and regional airports is underway during a scheduled network modernization (DES-2-27-1). The review is led by the airline network architects. The documented design gap: a dashboard reports all BGP peers up but real application transactions fail over a faulty service chain. The solution must proceed without losing the independently protected management path. Which ongoing architecture control best reduces recurrence of this gap?
Explanation
Correct Answer
The ongoing design assurance control is: Schedule end-to-end probes for critical service paths after changes. It is targeted at the documented risk: a dashboard reports all BGP peers up but real application transactions fail over a faulty service chain. The immediate design change is: Combine routing health with path tests and synthetic application service transactions. In subsequent reviews, validate recurrence prevention with: Tests identify the failing service segment despite stable routing adjacencies. Applied here, the relevant facts are: peers up but real application transactions fail over a faulty service chain. The solution must proceed without losing the independently protected management path.
Incorrect Answers
The alternate safeguard protects a separate dependency: The ongoing design assurance control is: Review intent-to-state drift alerts and their remediation time targets. For this failure the continuing exposure is: The ongoing design assurance control is: Schedule end-to-end probes for critical service paths after changes. Maintain “Schedule end-to-end probes for critical service paths after changes” instead.
That review tracks a separate failure mechanism: The ongoing design assurance control is: Correlate optics trends with maintenance events and link utilization. The question requires sustained control over: The ongoing design assurance control is: Schedule end-to-end probes for critical service paths after changes. The corresponding safeguard is “Schedule end-to-end probes for critical service paths after changes”.
This safeguard maintains a different technical control: The ongoing design assurance control is: Reevaluate critical control traffic classes when new applications are added. The recurring risk here is governed by: The ongoing design assurance control is: Schedule end-to-end probes for critical service paths after changes. The relevant review is “Schedule end-to-end probes for critical service paths after changes”.