McAfee Secure

Exam Code: JN0-481

Exam Name: Data Center, Specialist (JNCIS-DC)

Certification Provider: Juniper

Juniper JN0-481 Questions & Answers

Study with Up-To-Date REAL Exam Questions and Answers from the ACTUAL Test

65 Questions & Answers with Testing Engine

"Data Center, Specialist (JNCIS-DC) Exam", also known as JN0-481 exam, is a Juniper certification exam.

Pass your tests with the always up-to-date JN0-481 Exam Engine. Your JN0-481 training materials keep you at the head of the pack!

Satisfaction Guaranteed

Money Back Guarantee

Testking provides hassle-free money back guarantee with our products. That is because we have 100% trust in the abilities of our professional and experience product team, and our record is a proof of that.

99.6% PASS RATE
Was: $137.49
Now: $124.99

Juniper JN0-481 Practice Test 88

Question 870

One leaf's traffic encounters sporadic application latency while an IBA interface metric flags unexpected errors after a transceiver replacement. Once the issue is resolved, which ongoing practice BEST prevents this type of failure?

  1. Pair every analytics-triggered incident with recorded before-and-after probe and service evidence.
  2. Maintain a reviewed inventory of probe scopes, required telemetry sources and intended thresholds.
  3. Alert on counter trends separately from binary interface state and review optics during hardware changes.
  4. Reassess analytics thresholds after major workload, capacity or topology changes.

Explanation

Correct Answer

C:

This control reduces recurrence of the same class of failure: Interface error and discard telemetry can reveal degraded forwarding even while physical link state remains up. Apply the recurring practice: Alert on counter trends separately from binary interface state and review optics during hardware changes. The previous example was: One leaf's traffic encounters sporadic application latency while an IBA interface metric flags unexpected errors after a transceiver replacement.

Incorrect Answers

A:

Remediation should be verified using fresh metric observations and the intended network-service outcome, not the administrative success of a change alone. Here, interface error and discard telemetry can reveal degraded forwarding even while physical link state remains up.

B:

Maintain a reviewed inventory of probe scopes, required telemetry sources and intended thresholds. That concerns intent-Based Analytics probe definition, while the issue here is interface discard and error probe investigation. Inspect affected interface probes, device counters and optical or queue context, then isolate the actual transport or congestion condition.

D:

Reassess analytics thresholds after major workload, capacity or topology changes. Here, interface error and discard telemetry can reveal degraded forwarding even while physical link state remains up.

Question 871

A dashboard shows a stable green trend after device-agent communication stops, and the operator assumes the last available sample describes the current interface state. Which explanation BEST identifies the Juniper data-center or Apstra mechanism causing this result?

  1. Interface error and discard telemetry can reveal degraded forwarding even while physical link state remains up.
  2. A valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.
  3. Apstra Graph Explorer exposes modeled objects and relationships that can help trace which physical and virtual resources support a network service.
  4. Graph queries can select modeled Apstra resources and relationships using defined query constraints rather than enumerating every element by hand.

Explanation

Correct Answer

B:

A valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition. A new timestamped sample arrives and the probe evaluates current measurements rather than a stale cached value.

Incorrect Answers

A:

Interface error and discard telemetry can reveal degraded forwarding even while physical link state remains up. Here, a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

C:

Apstra Graph Explorer exposes modeled objects and relationships that can help trace which physical and virtual resources support a network service. For this issue, check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.

D:

Graph queries can select modeled Apstra resources and relationships using defined query constraints rather than enumerating every element by hand. Here, a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

Question 872

A dashboard shows a stable green trend after device-agent communication stops, and the operator assumes the last available sample describes the current interface state. Which configuration or operational action MOST directly addresses the problem?

  1. Correlate the specific probe and its target objects with service-level evidence, device state and path tests before assigning incident scope.
  2. Query the affected device's adjacent links and downstream virtual-network relationships, then verify the returned dependencies against current blueprint state.
  3. Check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.
  4. Create or select a supported probe for the relevant interface/error metric, bind its intended object scope and validate collection and evaluation.

Explanation

Correct Answer

C:

Check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods. The target behavior is demonstrated when a new timestamped sample arrives and the probe evaluates current measurements rather than a stale cached value.

Incorrect Answers

A:

Probe anomalies represent observations of defined metrics, while service health must be established from the relevant intent dependencies and traffic results. For this issue, check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.

B:

Query the affected device's adjacent links and downstream virtual-network relationships, then verify the returned dependencies against current blueprint state. Here, a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

D:

An Apstra IBA probe defines a supported analytical measurement or condition over selected network resources and requires appropriate source data. Here, a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

Question 873

A dashboard shows a stable green trend after device-agent communication stops, and the operator assumes the last available sample describes the current interface state. The team proposes: Check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods. Which data-center or operational principle BEST justifies that choice?

  1. A change is operationally successful only when the original measured symptom and dependent service impact are resolved.
  2. Link availability and forwarding quality are separate measurable properties of an IP fabric.
  3. The absence of an anomaly is not proof of service health when measurement coverage is unavailable.
  4. Query precision comes from explicit model relationships and conditions, not merely broad keyword matching.

Explanation

Correct Answer

C:

The absence of an anomaly is not proof of service health when measurement coverage is unavailable. It justifies the proposed change (Check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.) for the precise reported case: A dashboard shows a stable green trend after device-agent communication stops, and the operator assumes the last available sample describes the current interface state.

Incorrect Answers

A:

Remediation should be verified using fresh metric observations and the intended network-service outcome, not the administrative success of a change alone. For this issue, check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.

B:

Link availability and forwarding quality are separate measurable properties of an IP fabric. Here, a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

D:

The alternative applies to another Juniper security situation: A network engineer wants to find all leaf interfaces connected to one tagged rack group, but an unfiltered query returns unrelated spines and generic systems. That situation concerns graph queries can select modeled Apstra resources and relationships using defined query constraints rather than enumerating every element by hand. Its key condition is a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

Question 874

A dashboard shows a stable green trend after device-agent communication stops, and the operator assumes the last available sample describes the current interface state. After applying this change—Check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.—which observation BEST demonstrates success?

  1. The investigation identifies the relevant leaf and dependent service objects, supported by their actual observed conditions.
  2. A new timestamped sample arrives and the probe evaluates current measurements rather than a stale cached value.
  3. The change plan lists the correct impacted racks and tenant services while excluding a control tenant that does not depend on the device.
  4. The probe reports expected current measurements and produces a bounded test anomaly for the intentionally introduced failure condition.

Explanation

Correct Answer

B:

The configuration is not validated merely by a successful commit. A new timestamped sample arrives and the probe evaluates current measurements rather than a stale cached value. A valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

Incorrect Answers

A:

The investigation identifies the relevant leaf and dependent service objects, supported by their actual observed conditions. That concerns graph Explorer topology dependency inspection, while the issue here is probe telemetry freshness and missing samples. Check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.

C:

The change plan lists the correct impacted racks and tenant services while excluding a control tenant that does not depend on the device. Here, a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

D:

The probe reports expected current measurements and produces a bounded test anomaly for the intentionally introduced failure condition. That concerns intent-Based Analytics probe definition rather than probe telemetry freshness and missing samples. A new timestamped sample arrives and the probe evaluates current measurements rather than a stale cached value.

Question 875

A dashboard shows a stable green trend after device-agent communication stops, and the operator assumes the last available sample describes the current interface state. Once the issue is resolved, which ongoing practice BEST prevents this type of failure?

  1. Alert on counter trends separately from binary interface state and review optics during hardware changes.
  2. Monitor sample freshness and missing-telemetry conditions as first-class analytics health signals.
  3. Pair every analytics-triggered incident with recorded before-and-after probe and service evidence.
  4. Reassess analytics thresholds after major workload, capacity or topology changes.

Explanation

Correct Answer

B:

The preventive practice is aligned with the diagnosed mechanism, not an unrelated protection. Monitor sample freshness and missing-telemetry conditions as first-class analytics health signals. The absence of an anomaly is not proof of service health when measurement coverage is unavailable.

Incorrect Answers

A:

Interface error and discard telemetry can reveal degraded forwarding even while physical link state remains up. For the current prevention question, the evidence instead states: A dashboard shows a stable green trend after device-agent communication stops, and the operator assumes the last available sample describes the current interface state. Here, a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

C:

Remediation should be verified using fresh metric observations and the intended network-service outcome, not the administrative success of a change alone. However, the present prevention decision is grounded in: A dashboard shows a stable green trend after device-agent communication stops, and the operator assumes the last available sample describes the current interface state. For this issue, check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.

D:

Reassess analytics thresholds after major workload, capacity or topology changes. Here, a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

Question 876

A data center analytics rule produces no alarm because its measurement stream has missing data, yet the team treats silence as proof of healthy tenant latency. Which explanation BEST identifies the Juniper data-center or Apstra mechanism causing this result?

  1. Graph queries can select modeled Apstra resources and relationships using defined query constraints rather than enumerating every element by hand.
  2. A valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.
  3. Remediation should be verified using fresh metric observations and the intended network-service outcome, not the administrative success of a change alone.
  4. Interface error and discard telemetry can reveal degraded forwarding even while physical link state remains up.

Explanation

Correct Answer

B:

The decisive cause is a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition. Check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.

Incorrect Answers

A:

Graph queries can select modeled Apstra resources and relationships using defined query constraints rather than enumerating every element by hand. For the current diagnosis question, the evidence instead states: A data center analytics rule produces no alarm because its measurement stream has missing data, yet the team treats silence as proof of healthy tenant latency. Here, a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

C:

Remediation should be verified using fresh metric observations and the intended network-service outcome, not the administrative success of a change alone. However, the present diagnosis decision is grounded in: A data center analytics rule produces no alarm because its measurement stream has missing data, yet the team treats silence as proof of healthy tenant latency. For this issue, check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.

D:

This choice would be assessed for a different data-center fabric or Apstra operational situation: A fabric link shows healthy operational status but a rising discard counter, and an analyst assumes link-up means every packet is being delivered without loss. The present incident instead has this observed symptom: A data center analytics rule produces no alarm because its measurement stream has missing data, yet the team treats silence as proof of healthy tenant latency. Its decisive constraint is a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

Question 877

A data center analytics rule produces no alarm because its measurement stream has missing data, yet the team treats silence as proof of healthy tenant latency. Which configuration or operational action MOST directly addresses the problem?

  1. Check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.
  2. Query the affected device's adjacent links and downstream virtual-network relationships, then verify the returned dependencies against current blueprint state.
  3. Use the supported graph view to traverse the affected virtual network, devices, links and dependencies before isolating the fault.
  4. Create or select a supported probe for the relevant interface/error metric, bind its intended object scope and validate collection and evaluation.

Explanation

Correct Answer

A:

In this case, a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition. Check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods. A new timestamped sample arrives and the probe evaluates current measurements rather than a stale cached value.

Incorrect Answers

B:

This choice would be assessed for a different data-center fabric or Apstra operational situation: Before draining a leaf switch, a maintenance planner needs to identify affected generic systems and tenant virtual networks but searches only the switch interface configuration. The present incident instead has this observed symptom: A data center analytics rule produces no alarm because its measurement stream has missing data, yet the team treats silence as proof of healthy tenant latency. Its decisive constraint is a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

C:

Use the supported graph view to traverse the affected virtual network, devices, links and dependencies before isolating the fault. That concerns graph Explorer topology dependency inspection rather than probe telemetry freshness and missing samples. A new timestamped sample arrives and the probe evaluates current measurements rather than a stale cached value.

D:

An Apstra IBA probe defines a supported analytical measurement or condition over selected network resources and requires appropriate source data. For the current correction question, the evidence instead states: A data center analytics rule produces no alarm because its measurement stream has missing data, yet the team treats silence as proof of healthy tenant latency. Here, a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

Question 878

A data center analytics rule produces no alarm because its measurement stream has missing data, yet the team treats silence as proof of healthy tenant latency. The team proposes: Check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods. Which data-center or operational principle BEST justifies that choice?

  1. Link availability and forwarding quality are separate measurable properties of an IP fabric.
  2. Monitoring must distinguish ordinary seasonal variation from violations of an explicitly defined network behavior target.
  3. A change is operationally successful only when the original measured symptom and dependent service impact are resolved.
  4. The absence of an anomaly is not proof of service health when measurement coverage is unavailable.

Explanation

Correct Answer

D:

A data center analytics rule produces no alarm because its measurement stream has missing data, yet the team treats silence as proof of healthy tenant latency. The central principle is the absence of an anomaly is not proof of service health when measurement coverage is unavailable. Check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.

Incorrect Answers

A:

Interface error and discard telemetry can reveal degraded forwarding even while physical link state remains up. For this issue, check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.

B:

Monitoring must distinguish ordinary seasonal variation from violations of an explicitly defined network behavior target. Here, a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

C:

A change is operationally successful only when the original measured symptom and dependent service impact are resolved. That concerns verifying remediation against IBA evidence rather than probe telemetry freshness and missing samples. A new timestamped sample arrives and the probe evaluates current measurements rather than a stale cached value.

Question 879

A data center analytics rule produces no alarm because its measurement stream has missing data, yet the team treats silence as proof of healthy tenant latency. After applying this change—Check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.—which observation BEST demonstrates success?

  1. The investigation identifies the relevant leaf and dependent service objects, supported by their actual observed conditions.
  2. Returned objects match the approved rack or routing-zone scope and the query excludes a deliberate out-of-scope control object.
  3. The change plan lists the correct impacted racks and tenant services while excluding a control tenant that does not depend on the device.
  4. A new timestamped sample arrives and the probe evaluates current measurements rather than a stale cached value.

Explanation

Correct Answer

D:

A new timestamped sample arrives and the probe evaluates current measurements rather than a stale cached value. That tests the recommended change (Check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.) against the original case: A data center analytics rule produces no alarm because its measurement stream has missing data, yet the team treats silence as proof of healthy tenant latency.

Incorrect Answers

A:

This option addresses Graph Explorer topology dependency inspection rather than Probe telemetry freshness and missing samples. A relevant example for that other topic is: A virtual network reports failures after a leaf replacement, but the analyst looks at a flat rack list instead of following the relationships between the service, endpoints and managed devices. The more directly applicable response is: Check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.

B:

Graph queries can select modeled Apstra resources and relationships using defined query constraints rather than enumerating every element by hand. For this issue, check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.

C:

The change plan lists the correct impacted racks and tenant services while excluding a control tenant that does not depend on the device. Here, a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition. Specifically for the verification question, the case to validate is: A data center analytics rule produces no alarm because its measurement stream has missing data, yet the team treats silence as proof of healthy tenant latency.

Question 880

A data center analytics rule produces no alarm because its measurement stream has missing data, yet the team treats silence as proof of healthy tenant latency. Once the issue is resolved, which ongoing practice BEST prevents this type of failure?

  1. Reassess analytics thresholds after major workload, capacity or topology changes.
  2. Monitor sample freshness and missing-telemetry conditions as first-class analytics health signals.
  3. Pair every analytics-triggered incident with recorded before-and-after probe and service evidence.
  4. Document which IBA probes support each service SLO and where monitoring coverage has gaps.

Explanation

Correct Answer

B:

A lasting control should detect the original error before release. Monitor sample freshness and missing-telemetry conditions as first-class analytics health signals. That is important in this case because a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition. The scenario was: A data center analytics rule produces no alarm because its measurement stream has missing data, yet the team treats silence as proof of healthy tenant latency.

Incorrect Answers

A:

Anomaly alerting requires thresholds or reference baselines that reflect expected workload variation and supported probe semantics. Here, a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

C:

Remediation should be verified using fresh metric observations and the intended network-service outcome, not the administrative success of a change alone. However, the present prevention decision is grounded in: A data center analytics rule produces no alarm because its measurement stream has missing data, yet the team treats silence as proof of healthy tenant latency. For this issue, check probe data timestamps, agent health and collector scope, restore supported telemetry collection and identify unavailable periods.

D:

Document which IBA probes support each service SLO and where monitoring coverage has gaps. Here, a valid analytics conclusion depends on receiving timely samples from the selected device and monitoring pipeline, not simply on an existing probe definition.

Data Center, Specialist (JNCIS-DC) (JN0-481) Practice Tests