Question 1
At Fictional AlderArc Systems, during pre-production tenant onboarding in the west fabric pod, the SR Linux fabric team records the following exact evidence: A rack loses east-west connectivity when its only leaf uplink is removed during spine maintenance, despite a second spine being available in the room. Which underlying technical issue BEST explains the observed result?
Explanation
Correct Answer
The directly supported underlying mechanism is: The leaf is single-homed to one spine, so the supposed Clos topology lacks an independent routed path to the other spine. The relevant Nokia data center fabric design principle is: A resilient leaf-spine fabric provides redundant Layer 3 paths between leaves rather than relying on a single shared uplink. The scoped correction is: Connect the leaf with routed uplinks to separate spines and establish the required underlay adjacencies over both physical paths. Confirm the outcome by checking: After removing either one spine uplink, traffic between test hosts on different leaves still succeeds over the remaining path.
Incorrect Answers
This alternative concerns “The topology extends a flat Layer 2 domain through aggregation instead of using Layer 3 routing with ECMP between leaves and spines.” The recorded evidence is “A rack loses east-west connectivity when its only leaf uplink is removed during spine maintenance, despite a second spine being available in the room.” For this root-cause diagnosis, the more directly supported distinction is “The leaf is single-homed to one spine, so the supposed Clos topology lacks an independent routed path to the other spine”; the alternative does not explain the stated condition.
This diagnosis alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A newly installed leaf responds to its directly connected network but never learns rack prefixes beyond its local subnet. That other situation is caused by: Its routed leaf-to-spine interfaces are up, but the planned BGP underlay neighbor sessions have not been established. Therefore the relevant diagnosis decision here is: The leaf is single-homed to one spine, so the supposed Clos topology lacks an independent routed path to the other spine. The proposed alternative does not directly address or establish that specific outcome.
This alternative concerns “The proposed AS assignment overlooks the specific eBGP adjacency model and can create incorrect AS-path loop behavior.” The recorded evidence is “A rack loses east-west connectivity when its only leaf uplink is removed during spine maintenance, despite a second spine being available in the room.” For this root-cause diagnosis, the more directly supported distinction is “The leaf is single-homed to one spine, so the supposed Clos topology lacks an independent routed path to the other spine”; the alternative does not explain the stated condition.