Question 390
At Fictional JuniperHorizon Energy, during post-maintenance resilience review in the east fabric pod, the SR Linux fabric team records the following exact evidence: BGP peers flap every few seconds while interfaces stay stable; BFD diagnostics show intermittent misses during supervisor load. Which scoped engineering response BEST addresses the underlying problem?
Explanation
Correct Answer
For the Fictional JuniperHorizon Energy post-maintenance resilience review in the east fabric pod, the evidence is: BGP peers flap every few seconds while interfaces stay stable; BFD diagnostics show intermittent misses during supervisor load. The causal technical issue is: Aggressive BFD detection settings exceed the peer or platform capability under temporary CPU scheduling delays. The focused corrective engineering response is: Review negotiated BFD detection multipliers and timers and tune them to supported failover and load requirements. The governing engineering principle is: BFD should detect genuine adjacency failure promptly without producing excessive false failure events. The acceptance check is: BFD remains stable under representative load and a real test link failure still triggers bounded convergence.
Incorrect Answers
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: One leaf believes BFD is required for BGP but its peer does not establish the expected BFD session, causing avoidable down events. That other situation is caused by: Peer BFD configuration or reachable endpoint expectations do not match across the BGP adjacency. The actual Fictional JuniperHorizon Energy case instead says: BGP peers flap every few seconds while interfaces stay stable; BFD diagnostics show intermittent misses during supervisor load. Therefore the relevant correction decision here is: Review negotiated BFD detection multipliers and timers and tune them to supported failover and load requirements. The proposed alternative does not directly address or establish that specific outcome.
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A VTEP receives VXLAN packets but places them in a different service than the source leaf intended. That other situation is caused by: The participating leaf nodes map the same tenant to inconsistent VXLAN network identifiers. The actual Fictional JuniperHorizon Energy case instead says: BGP peers flap every few seconds while interfaces stay stable; BFD diagnostics show intermittent misses during supervisor load. Therefore the relevant correction decision here is: Review negotiated BFD detection multipliers and timers and tune them to supported failover and load requirements. The proposed alternative does not directly address or establish that specific outcome.
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: An operator sees a local MAC entry and concludes a remote leaf must know it, but no EVPN MAC/IP route exists upstream. That other situation is caused by: The locally learned endpoint is not being advertised into the required EVPN address family or tenant service context. The actual Fictional JuniperHorizon Energy case instead says: BGP peers flap every few seconds while interfaces stay stable; BFD diagnostics show intermittent misses during supervisor load. Therefore the relevant correction decision here is: Review negotiated BFD detection multipliers and timers and tune them to supported failover and load requirements. The proposed alternative does not directly address or establish that specific outcome.