Question 550
At Fictional NorthHorizon Energy, during post-maintenance resilience review in the east fabric pod, the SR Linux fabric team records the following exact evidence: A broad deny statement at the top of an interface ACL causes an approved application to lose reachability. Which scoped engineering response BEST addresses the underlying problem?
Explanation
Correct Answer
For the Fictional NorthHorizon Energy post-maintenance resilience review in the east fabric pod, the evidence is: A broad deny statement at the top of an interface ACL causes an approved application to lose reachability. The causal technical issue is: The first matching rule rejects the application before its later permit rule can be considered. The focused corrective engineering response is: Place narrower intended exceptions in the correct precedence and preserve a reviewed default policy. The governing engineering principle is: Ordered ACL rule evaluation makes match precedence essential to effective packet permissions. The acceptance check is: The known authorized application works and a disallowed test flow remains blocked.
Incorrect Answers
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: IPv4 traffic is properly filtered on a server-facing attachment while equivalent IPv6 traffic bypasses the intended restriction. That other situation is caused by: The policy and testing cover only IPv4 match criteria and omit the separate IPv6 traffic path. The actual Fictional NorthHorizon Energy case instead says: A broad deny statement at the top of an interface ACL causes an approved application to lose reachability. Therefore the relevant correction decision here is: Place narrower intended exceptions in the correct precedence and preserve a reviewed default policy. The proposed alternative does not directly address or establish that specific outcome.
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A new system ACL blocks the monitoring collector from reaching an authorized management port and telemetry disappears. That other situation is caused by: A required collector source was omitted from the management service allowlist in the system ACL. The actual Fictional NorthHorizon Energy case instead says: A broad deny statement at the top of an interface ACL causes an approved application to lose reachability. Therefore the relevant correction decision here is: Place narrower intended exceptions in the correct precedence and preserve a reviewed default policy. The proposed alternative does not directly address or establish that specific outcome.
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: BGP liveness fails immediately after a strict CPM-filter rollout, although direct IP connectivity and neighbor configuration remain correct. That other situation is caused by: The control-plane policy unintentionally drops the required routing or BFD packets at the local processor path. The actual Fictional NorthHorizon Energy case instead says: A broad deny statement at the top of an interface ACL causes an approved application to lose reachability. Therefore the relevant correction decision here is: Place narrower intended exceptions in the correct precedence and preserve a reviewed default policy. The proposed alternative does not directly address or establish that specific outcome.