Question 590
At Fictional OakHorizon Energy, during post-maintenance resilience review in the east fabric pod, the SR Linux fabric team records the following exact evidence: BGP liveness fails immediately after a strict CPM-filter rollout, although direct IP connectivity and neighbor configuration remain correct. Which scoped engineering response BEST addresses the underlying problem?
Explanation
Correct Answer
For the Fictional OakHorizon Energy post-maintenance resilience review in the east fabric pod, the evidence is: BGP liveness fails immediately after a strict CPM-filter rollout, although direct IP connectivity and neighbor configuration remain correct. The causal technical issue is: The control-plane policy unintentionally drops the required routing or BFD packets at the local processor path. The focused corrective engineering response is: Permit the required protocol traffic with scoped control-plane rules and suitable policers before reapplying the filter. The governing engineering principle is: Local protocol sessions need explicit control-plane treatment and cannot rely on data-plane forwarding permits. The acceptance check is: BGP and BFD sessions remain stable and unwanted control-plane probes are still restricted.
Incorrect Answers
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A port security policy is intended only for a server VLAN but the proposed ACL change also disrupts all fabric uplinks. That other situation is caused by: The ACL or CPM filter was applied to an overly broad interface group rather than the selected server-facing attachment. The actual Fictional OakHorizon Energy case instead says: BGP liveness fails immediately after a strict CPM-filter rollout, although direct IP connectivity and neighbor configuration remain correct. Therefore the relevant correction decision here is: Permit the required protocol traffic with scoped control-plane rules and suitable policers before reapplying the filter. The proposed alternative does not directly address or establish that specific outcome.
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: An engineer initiates a capture-filter for the affected tenant but the pcap contains only unrelated uplink traffic. That other situation is caused by: The capture filter matches the wrong interface/VLAN or address criteria for the intended packet path. The actual Fictional OakHorizon Energy case instead says: BGP liveness fails immediately after a strict CPM-filter rollout, although direct IP connectivity and neighbor configuration remain correct. Therefore the relevant correction decision here is: Permit the required protocol traffic with scoped control-plane rules and suitable policers before reapplying the filter. The proposed alternative does not directly address or establish that specific outcome.
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: An operator sees a BGP reset in routing telemetry but cannot find the event in the expected centralized log stream. That other situation is caused by: The SR Linux logging configuration sends the relevant event category to a different local or remote destination. The actual Fictional OakHorizon Energy case instead says: BGP liveness fails immediately after a strict CPM-filter rollout, although direct IP connectivity and neighbor configuration remain correct. Therefore the relevant correction decision here is: Permit the required protocol traffic with scoped control-plane rules and suitable policers before reapplying the filter. The proposed alternative does not directly address or establish that specific outcome.