Question 110
At Fictional CedarHorizon Energy, during post-maintenance resilience review in the east fabric pod, the SR Linux fabric team records the following exact evidence: A fabric operator cannot determine which tenants will be affected by shutting down a leaf for maintenance. Which scoped engineering response BEST addresses the underlying problem?
Explanation
Correct Answer
For the Fictional CedarHorizon Energy post-maintenance resilience review in the east fabric pod, the evidence is: A fabric operator cannot determine which tenants will be affected by shutting down a leaf for maintenance. The causal technical issue is: Configuration and service dependencies are tracked in disconnected local notes rather than a mapped fabric service inventory. The focused corrective engineering response is: Associate tenant services and attachment points with managed fabric nodes and use dependency-aware maintenance planning. The governing engineering principle is: Multi-device fabric operations need traceability between physical resources, tenants and intended services. The acceptance check is: The change preview lists the expected impacted tenant attachments and matches a manually verified spot-check sample.
Incorrect Answers
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: Fabric Services System reports a deployment as successful, but a new tenant workload still uses an older service profile. That other situation is caused by: The manager pushed intended fabric configuration without reconciling a stale tenant service assignment and its effective state. The actual Fictional CedarHorizon Energy case instead says: A fabric operator cannot determine which tenants will be affected by shutting down a leaf for maintenance. Therefore the relevant correction decision here is: Associate tenant services and attachment points with managed fabric nodes and use dependency-aware maintenance planning. The proposed alternative does not directly address or establish that specific outcome.
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A rack loses east-west connectivity when its only leaf uplink is removed during spine maintenance, despite a second spine being available in the room. That other situation is caused by: The leaf is single-homed to one spine, so the supposed Clos topology lacks an independent routed path to the other spine. The actual Fictional CedarHorizon Energy case instead says: A fabric operator cannot determine which tenants will be affected by shutting down a leaf for maintenance. Therefore the relevant correction decision here is: Associate tenant services and attachment points with managed fabric nodes and use dependency-aware maintenance planning. The proposed alternative does not directly address or establish that specific outcome.
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: Cross-rack latency doubles during peak east-west traffic because all rack-to-rack packets pass through a remote aggregation gateway. That other situation is caused by: The network design hairpins server-to-server traffic through a centralized aggregation point rather than forwarding through the local Clos spine layer. The actual Fictional CedarHorizon Energy case instead says: A fabric operator cannot determine which tenants will be affected by shutting down a leaf for maintenance. Therefore the relevant correction decision here is: Associate tenant services and attachment points with managed fabric nodes and use dependency-aware maintenance planning. The proposed alternative does not directly address or establish that specific outcome.