Question 230
At Fictional FoxHorizon Energy, during post-maintenance resilience review in the east fabric pod, the SR Linux fabric team records the following exact evidence: A fabric uplink is operational at the optic layer but all routed traffic fails after IP addressing is configured on an unintended sub-interface. Which scoped engineering response BEST addresses the underlying problem?
Explanation
Correct Answer
For the Fictional FoxHorizon Energy post-maintenance resilience review in the east fabric pod, the evidence is: A fabric uplink is operational at the optic layer but all routed traffic fails after IP addressing is configured on an unintended sub-interface. The causal technical issue is: The L3 address is bound to the wrong logical interface, so packets do not use the expected encapsulation path. The focused corrective engineering response is: Bind the intended IP address and network-instance relationship to the correct interface/sub-interface. The governing engineering principle is: Routing adjacency requires correct mapping between physical ports, logical encapsulation and L3 configuration. The acceptance check is: A peer ARP or neighbor entry and subsequent routed adjacency appear on the approved logical interface.
Incorrect Answers
“Assign nonoverlapping VLAN matching criteria and verify each sub-interface points to the correct service” addresses a different corrective need. The documented situation is “A fabric uplink is operational at the optic layer but all routed traffic fails after IP addressing is configured on an unintended sub-interface.” The better-matched targeted correction is “Bind the intended IP address and network-instance relationship to the correct interface/sub-interface,” because it deals with the specific problem described rather than an adjacent issue.
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: Service throughput collapses but BGP remains established; interface counters show growing CRC errors on a single underlay link. That other situation is caused by: A physical-layer bit-error condition degrades packet transport even though control sessions have not yet timed out. The actual Fictional FoxHorizon Energy case instead says: A fabric uplink is operational at the optic layer but all routed traffic fails after IP addressing is configured on an unintended sub-interface. Therefore the relevant correction decision here is: Bind the intended IP address and network-instance relationship to the correct interface/sub-interface. The proposed alternative does not directly address or establish that specific outcome.
“Inspect and repair the tenant IP-VRF route import or static routing configuration in its own context” addresses a different corrective need. The documented situation is “A fabric uplink is operational at the optic layer but all routed traffic fails after IP addressing is configured on an unintended sub-interface.” The better-matched targeted correction is “Bind the intended IP address and network-instance relationship to the correct interface/sub-interface,” because it deals with the specific problem described rather than an adjacent issue.