Question 250
At Fictional GraniteCanyon Health, during pre-production tenant onboarding in the west fabric pod, the SR Linux fabric team records the following exact evidence: Service throughput collapses but BGP remains established; interface counters show growing CRC errors on a single underlay link. Which scoped engineering response BEST addresses the underlying problem?
Explanation
Correct Answer
The causal technical issue is: A physical-layer bit-error condition degrades packet transport even though control sessions have not yet timed out. The focused corrective engineering response is: Check optics/fiber and FEC compatibility, repair the impaired link, and validate counters under traffic. The governing engineering principle is: Control-plane neighbor uptime alone does not prove healthy data-plane physical transport. The acceptance check is: CRC or FCS error counters stop increasing and controlled throughput returns over the repaired link.
Incorrect Answers
“Inspect IPv6 interfaces, next-hop resolution and IPv6 route advertisements in addition to IPv4 state” addresses a different corrective need. The documented situation is “Service throughput collapses but BGP remains established; interface counters show growing CRC errors on a single underlay link.” The better-matched targeted correction is “Check optics/fiber and FEC compatibility, repair the impaired link, and validate counters under traffic,” because it deals with the specific problem described rather than an adjacent issue.
“Move each routed attachment to its authorized IP-VRF and review overlay service bindings” addresses a different corrective need. The documented situation is “Service throughput collapses but BGP remains established; interface counters show growing CRC errors on a single underlay link.” The better-matched targeted correction is “Check optics/fiber and FEC compatibility, repair the impaired link, and validate counters under traffic,” because it deals with the specific problem described rather than an adjacent issue.
“Find the duplicated or moving endpoint and apply appropriately tuned MAC move protection while correcting the access attachment” addresses a different corrective need. The documented situation is “Service throughput collapses but BGP remains established; interface counters show growing CRC errors on a single underlay link.” The better-matched targeted correction is “Check optics/fiber and FEC compatibility, repair the impaired link, and validate counters under traffic,” because it deals with the specific problem described rather than an adjacent issue.