Nokia 4A0-D01 Practice Test 7

Question 60

At Fictional BriarEstuary Media, during pre-production tenant onboarding in the west fabric pod, the SR Linux fabric team records the following exact evidence: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. Which recurring operational safeguard BEST reduces the chance of the same failure happening again?

  1. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarEstuary Media, review automation against supported SR Linux data models and reject unmanaged host-file configuration workflows.
  2. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarEstuary Media, add API-schema compatibility and response-contract tests to every automation release.
  3. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarEstuary Media, reconcile discovery against design inventory as a required deployment acceptance control.
  4. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarEstuary Media, use a per-tenant VNI/route-target inventory and verify cross-leaf reachability during service changes.

Explanation

Correct Answer

D:

The technical mechanism is: The tenant Layer 2 service lacks consistent EVPN route distribution or VXLAN network identifier mapping across leaves. The recurrence-prevention control most closely connected to this root problem is: Use a per-tenant VNI/route-target inventory and verify cross-leaf reachability during service changes. This complements the immediate repair: Align VNI and associated EVPN membership/route-target configuration for the tenant on the participating leaves. It is justified by the design rule: VXLAN carries overlay frames while EVPN advertises the endpoint reachability needed across the routed underlay. Confirm the repair via: The remote leaf learns the tenant MAC reachability and a moved test host communicates across racks without bridging transit links.

Incorrect Answers

A:

The safeguard “Review automation against supported SR Linux data models and reject unmanaged host-file configuration workflows” is directed at another failure. This case records “Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf.” The more relevant preventive control is “Use a per-tenant VNI/route-target inventory and verify cross-leaf reachability during service changes,” because it follows the recorded cause rather than a different operational problem.

B:

The safeguard “Add API-schema compatibility and response-contract tests to every automation release” is directed at another failure. This case records “Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf.” The more relevant preventive control is “Use a per-tenant VNI/route-target inventory and verify cross-leaf reachability during service changes,” because it follows the recorded cause rather than a different operational problem.

C:

The safeguard “Reconcile discovery against design inventory as a required deployment acceptance control” is directed at another failure. This case records “Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf.” The more relevant preventive control is “Use a per-tenant VNI/route-target inventory and verify cross-leaf reachability during service changes,” because it follows the recorded cause rather than a different operational problem.

Question 61

At Fictional BriarForge Manufacturing, during post-maintenance resilience review in the east fabric pod, the SR Linux fabric team records the following exact evidence: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. Which underlying technical issue BEST explains the observed result?

  1. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, the tenant Layer 2 service lacks consistent EVPN route distribution or VXLAN network identifier mapping across leaves.
  2. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, the runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state.
  3. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, the application relies on unstable human-oriented output instead of the documented structured SR Linux interface.
  4. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, the operational inventory lacks reconciled physical topology, node identity and intended endpoint relationships.

Explanation

Correct Answer

A:

The Fictional BriarForge Manufacturing case records: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. The directly supported underlying mechanism is: The tenant Layer 2 service lacks consistent EVPN route distribution or VXLAN network identifier mapping across leaves. The relevant Nokia data center fabric design principle is: VXLAN carries overlay frames while EVPN advertises the endpoint reachability needed across the routed underlay. The scoped correction is: Align VNI and associated EVPN membership/route-target configuration for the tenant on the participating leaves. Confirm the outcome by checking: The remote leaf learns the tenant MAC reachability and a moved test host communicates across racks without bridging transit links.

Incorrect Answers

B:

This diagnosis alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime. That other situation is caused by: The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state. The actual Fictional BriarForge Manufacturing case instead says: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. Therefore the relevant diagnosis decision here is: The tenant Layer 2 service lacks consistent EVPN route distribution or VXLAN network identifier mapping across leaves. The proposed alternative does not directly address or establish that specific outcome.

C:

This diagnosis alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: An external fabric automation program tries to automate by parsing interactive screen prompts and fails when CLI presentation changes. That other situation is caused by: The application relies on unstable human-oriented output instead of the documented structured SR Linux interface. The actual Fictional BriarForge Manufacturing case instead says: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. Therefore the relevant diagnosis decision here is: The tenant Layer 2 service lacks consistent EVPN route distribution or VXLAN network identifier mapping across leaves. The proposed alternative does not directly address or establish that specific outcome.

D:

This diagnosis alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A new fabric deployment has correct leaf and spine cabling but its inventory service reports no relationships between devices. That other situation is caused by: The operational inventory lacks reconciled physical topology, node identity and intended endpoint relationships. The actual Fictional BriarForge Manufacturing case instead says: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. Therefore the relevant diagnosis decision here is: The tenant Layer 2 service lacks consistent EVPN route distribution or VXLAN network identifier mapping across leaves. The proposed alternative does not directly address or establish that specific outcome.

Question 62

At Fictional BriarForge Manufacturing, during post-maintenance resilience review in the east fabric pod, the SR Linux fabric team records the following exact evidence: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. Which scoped engineering response BEST addresses the underlying problem?

  1. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, apply supported SR Linux CLI or model-based API operations to the appropriate configuration datastore and commit the change.
  2. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, align VNI and associated EVPN membership/route-target configuration for the tenant on the participating leaves.
  3. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, use a supported model-driven API such as gNMI or JSON-RPC with explicit schema handling and authenticated access.
  4. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, import authoritative device identity and topology information into the fabric management system and reconcile observed links.

Explanation

Correct Answer

B:

For the Fictional BriarForge Manufacturing post-maintenance resilience review in the east fabric pod, the evidence is: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. The causal technical issue is: The tenant Layer 2 service lacks consistent EVPN route distribution or VXLAN network identifier mapping across leaves. The focused corrective engineering response is: Align VNI and associated EVPN membership/route-target configuration for the tenant on the participating leaves. The governing engineering principle is: VXLAN carries overlay frames while EVPN advertises the endpoint reachability needed across the routed underlay. The acceptance check is: The remote leaf learns the tenant MAC reachability and a moved test host communicates across racks without bridging transit links.

Incorrect Answers

A:

This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime. That other situation is caused by: The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state. The actual Fictional BriarForge Manufacturing case instead says: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. Therefore the relevant correction decision here is: Align VNI and associated EVPN membership/route-target configuration for the tenant on the participating leaves. The proposed alternative does not directly address or establish that specific outcome.

C:

“Use a supported model-driven API such as gNMI or JSON-RPC with explicit schema handling and authenticated access” addresses a different corrective need. The documented situation is “Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf.” The better-matched targeted correction is “Align VNI and associated EVPN membership/route-target configuration for the tenant on the participating leaves,” because it deals with the specific problem described rather than an adjacent issue.

D:

“Import authoritative device identity and topology information into the fabric management system and reconcile observed links” addresses a different corrective need. The documented situation is “Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf.” The better-matched targeted correction is “Align VNI and associated EVPN membership/route-target configuration for the tenant on the participating leaves,” because it deals with the specific problem described rather than an adjacent issue.

Question 63

At Fictional BriarForge Manufacturing, during post-maintenance resilience review in the east fabric pod, the SR Linux fabric team records the following exact evidence: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. Which directly observable result BEST demonstrates that the problem has been resolved?

  1. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, the modeled configuration shows the intended route instance after commit and operational verification reflects the change.
  2. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, the controller can read and modify a lab test setting through the supported API and validate its resulting operational state.
  3. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, the remote leaf learns the tenant MAC reachability and a moved test host communicates across racks without bridging transit links.
  4. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, observed switch and uplink relationships match the intended topology graph and missing-link alarms resolve.

Explanation

Correct Answer

C:

In the Fictional BriarForge Manufacturing case, the reported symptom is: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. A correct fix must address: The tenant Layer 2 service lacks consistent EVPN route distribution or VXLAN network identifier mapping across leaves. The directly relevant evidence of successful remediation is: The remote leaf learns the tenant MAC reachability and a moved test host communicates across racks without bridging transit links. This proves the intended result of the response: Align VNI and associated EVPN membership/route-target configuration for the tenant on the participating leaves. The relevant design principle is: VXLAN carries overlay frames while EVPN advertises the endpoint reachability needed across the routed underlay.

Incorrect Answers

A:

This verification alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime. That other situation is caused by: The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state. The actual Fictional BriarForge Manufacturing case instead says: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. Therefore the relevant verification decision here is: The remote leaf learns the tenant MAC reachability and a moved test host communicates across racks without bridging transit links. The proposed alternative does not directly address or establish that specific outcome.

B:

The offered check, “The controller can read and modify a lab test setting through the supported API and validate its resulting operational state,” would test a separate condition. The recorded issue is “Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf.” The directly relevant verification is “The remote leaf learns the tenant MAC reachability and a moved test host communicates across racks without bridging transit links”; passing the alternative check would not establish that this issue was addressed.

D:

The offered check, “Observed switch and uplink relationships match the intended topology graph and missing-link alarms resolve,” would test a separate condition. The recorded issue is “Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf.” The directly relevant verification is “The remote leaf learns the tenant MAC reachability and a moved test host communicates across racks without bridging transit links”; passing the alternative check would not establish that this issue was addressed.

Question 64

At Fictional BriarForge Manufacturing, during post-maintenance resilience review in the east fabric pod, the SR Linux fabric team records the following exact evidence: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. Which recurring operational safeguard BEST reduces the chance of the same failure happening again?

  1. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, review automation against supported SR Linux data models and reject unmanaged host-file configuration workflows.
  2. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, add API-schema compatibility and response-contract tests to every automation release.
  3. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, reconcile discovery against design inventory as a required deployment acceptance control.
  4. For the post-maintenance resilience review in the east fabric pod at Fictional BriarForge Manufacturing, use a per-tenant VNI/route-target inventory and verify cross-leaf reachability during service changes.

Explanation

Correct Answer

D:

For Fictional BriarForge Manufacturing, the exact reported evidence is: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. The technical mechanism is: The tenant Layer 2 service lacks consistent EVPN route distribution or VXLAN network identifier mapping across leaves. The recurrence-prevention control most closely connected to this root problem is: Use a per-tenant VNI/route-target inventory and verify cross-leaf reachability during service changes. This complements the immediate repair: Align VNI and associated EVPN membership/route-target configuration for the tenant on the participating leaves. It is justified by the design rule: VXLAN carries overlay frames while EVPN advertises the endpoint reachability needed across the routed underlay. Confirm the repair via: The remote leaf learns the tenant MAC reachability and a moved test host communicates across racks without bridging transit links.

Incorrect Answers

A:

This prevention alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime. That other situation is caused by: The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state. The actual Fictional BriarForge Manufacturing case instead says: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. Therefore the relevant prevention decision here is: Use a per-tenant VNI/route-target inventory and verify cross-leaf reachability during service changes. The proposed alternative does not directly address or establish that specific outcome.

B:

This prevention alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: An external fabric automation program tries to automate by parsing interactive screen prompts and fails when CLI presentation changes. That other situation is caused by: The application relies on unstable human-oriented output instead of the documented structured SR Linux interface. The actual Fictional BriarForge Manufacturing case instead says: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. Therefore the relevant prevention decision here is: Use a per-tenant VNI/route-target inventory and verify cross-leaf reachability during service changes. The proposed alternative does not directly address or establish that specific outcome.

C:

This prevention alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A new fabric deployment has correct leaf and spine cabling but its inventory service reports no relationships between devices. That other situation is caused by: The operational inventory lacks reconciled physical topology, node identity and intended endpoint relationships. The actual Fictional BriarForge Manufacturing case instead says: Hosts in the same logical tenant network can exchange packets on one rack but cannot communicate after moving to another leaf. Therefore the relevant prevention decision here is: Use a per-tenant VNI/route-target inventory and verify cross-leaf reachability during service changes. The proposed alternative does not directly address or establish that specific outcome.

Question 65

At Fictional BriarGrove Analytics, during pre-production tenant onboarding in the west fabric pod, the SR Linux fabric team records the following exact evidence: A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime. Which underlying technical issue BEST explains the observed result?

  1. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, the runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state.
  2. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, the deployment plan copied a platform-independent port map without checking the actual hardware-specific interface inventory and capabilities.
  3. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, the automation identity has monitoring privileges but not the authorized configuration role needed for write operations.
  4. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, configuration and service dependencies are tracked in disconnected local notes rather than a mapped fabric service inventory.

Explanation

Correct Answer

A:

The directly supported underlying mechanism is: The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state. The relevant Nokia data center fabric design principle is: SR Linux exposes device configuration and operational state through structured models rather than unsupported file edits. The scoped correction is: Apply supported SR Linux CLI or model-based API operations to the appropriate configuration datastore and commit the change. Confirm the outcome by checking: The modeled configuration shows the intended route instance after commit and operational verification reflects the change.

Incorrect Answers

B:

This alternative concerns “The deployment plan copied a platform-independent port map without checking the actual hardware-specific interface inventory and capabilities.” The recorded evidence is “A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime.” For this root-cause diagnosis, the more directly supported distinction is “The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state”; the alternative does not explain the stated condition.

C:

This diagnosis alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A provisioning controller can read a router state through gNMI but all attempted configuration changes are denied. That other situation is caused by: The automation identity has monitoring privileges but not the authorized configuration role needed for write operations. Therefore the relevant diagnosis decision here is: The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state. The proposed alternative does not directly address or establish that specific outcome.

D:

This diagnosis alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A fabric operator cannot determine which tenants will be affected by shutting down a leaf for maintenance. That other situation is caused by: Configuration and service dependencies are tracked in disconnected local notes rather than a mapped fabric service inventory. Therefore the relevant diagnosis decision here is: The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state. The proposed alternative does not directly address or establish that specific outcome.

Question 66

At Fictional BriarGrove Analytics, during pre-production tenant onboarding in the west fabric pod, the SR Linux fabric team records the following exact evidence: A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime. Which scoped engineering response BEST addresses the underlying problem?

  1. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, validate the target model, port numbering, supported speeds and transceiver constraints before applying the port migration plan.
  2. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, apply supported SR Linux CLI or model-based API operations to the appropriate configuration datastore and commit the change.
  3. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, grant only the narrow permitted configuration role to the controller identity and apply requests to the proper datastore.
  4. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, associate tenant services and attachment points with managed fabric nodes and use dependency-aware maintenance planning.

Explanation

Correct Answer

B:

The causal technical issue is: The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state. The focused corrective engineering response is: Apply supported SR Linux CLI or model-based API operations to the appropriate configuration datastore and commit the change. The governing engineering principle is: SR Linux exposes device configuration and operational state through structured models rather than unsupported file edits. The acceptance check is: The modeled configuration shows the intended route instance after commit and operational verification reflects the change.

Incorrect Answers

A:

“Validate the target model, port numbering, supported speeds and transceiver constraints before applying the port migration plan” addresses a different corrective need. The documented situation is “A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime.” The better-matched targeted correction is “Apply supported SR Linux CLI or model-based API operations to the appropriate configuration datastore and commit the change,” because it deals with the specific problem described rather than an adjacent issue.

C:

This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A provisioning controller can read a router state through gNMI but all attempted configuration changes are denied. That other situation is caused by: The automation identity has monitoring privileges but not the authorized configuration role needed for write operations. Therefore the relevant correction decision here is: Apply supported SR Linux CLI or model-based API operations to the appropriate configuration datastore and commit the change. The proposed alternative does not directly address or establish that specific outcome.

D:

This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A fabric operator cannot determine which tenants will be affected by shutting down a leaf for maintenance. That other situation is caused by: Configuration and service dependencies are tracked in disconnected local notes rather than a mapped fabric service inventory. Therefore the relevant correction decision here is: Apply supported SR Linux CLI or model-based API operations to the appropriate configuration datastore and commit the change. The proposed alternative does not directly address or establish that specific outcome.

Question 67

At Fictional BriarGrove Analytics, during pre-production tenant onboarding in the west fabric pod, the SR Linux fabric team records the following exact evidence: A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime. Which directly observable result BEST demonstrates that the problem has been resolved?

  1. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, the live port inventory matches the approved cabling map and all intended interfaces negotiate supported operational parameters.
  2. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, read-only telemetry remains available and an approved test configuration change succeeds only for the authorized controller role.
  3. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, the modeled configuration shows the intended route instance after commit and operational verification reflects the change.
  4. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, the change preview lists the expected impacted tenant attachments and matches a manually verified spot-check sample.

Explanation

Correct Answer

C:

A correct fix must address: The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state. The directly relevant evidence of successful remediation is: The modeled configuration shows the intended route instance after commit and operational verification reflects the change. This proves the intended result of the response: Apply supported SR Linux CLI or model-based API operations to the appropriate configuration datastore and commit the change. The relevant design principle is: SR Linux exposes device configuration and operational state through structured models rather than unsupported file edits.

Incorrect Answers

A:

This verification alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A data center standard assumes that a 7220 IXR and a 7250 IXR have interchangeable physical port layouts during a staged cabling swap. That other situation is caused by: The deployment plan copied a platform-independent port map without checking the actual hardware-specific interface inventory and capabilities. Therefore the relevant verification decision here is: The modeled configuration shows the intended route instance after commit and operational verification reflects the change. The proposed alternative does not directly address or establish that specific outcome.

B:

This verification alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A provisioning controller can read a router state through gNMI but all attempted configuration changes are denied. That other situation is caused by: The automation identity has monitoring privileges but not the authorized configuration role needed for write operations. Therefore the relevant verification decision here is: The modeled configuration shows the intended route instance after commit and operational verification reflects the change. The proposed alternative does not directly address or establish that specific outcome.

D:

This verification alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A fabric operator cannot determine which tenants will be affected by shutting down a leaf for maintenance. That other situation is caused by: Configuration and service dependencies are tracked in disconnected local notes rather than a mapped fabric service inventory. Therefore the relevant verification decision here is: The modeled configuration shows the intended route instance after commit and operational verification reflects the change. The proposed alternative does not directly address or establish that specific outcome.

Question 68

At Fictional BriarGrove Analytics, during pre-production tenant onboarding in the west fabric pod, the SR Linux fabric team records the following exact evidence: A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime. Which recurring operational safeguard BEST reduces the chance of the same failure happening again?

  1. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, maintain a platform-specific BOM, interface map and optics qualification test for every switch model.
  2. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, exercise least-privilege read-versus-write API tests in service-account reviews.
  3. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, require service-to-device dependency audits before approving fabric-wide change windows.
  4. For the pre-production tenant onboarding in the west fabric pod at Fictional BriarGrove Analytics, review automation against supported SR Linux data models and reject unmanaged host-file configuration workflows.

Explanation

Correct Answer

D:

The technical mechanism is: The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state. The recurrence-prevention control most closely connected to this root problem is: Review automation against supported SR Linux data models and reject unmanaged host-file configuration workflows. This complements the immediate repair: Apply supported SR Linux CLI or model-based API operations to the appropriate configuration datastore and commit the change. It is justified by the design rule: SR Linux exposes device configuration and operational state through structured models rather than unsupported file edits. Confirm the repair via: The modeled configuration shows the intended route instance after commit and operational verification reflects the change.

Incorrect Answers

A:

The safeguard “Maintain a platform-specific BOM, interface map and optics qualification test for every switch model” is directed at another failure. This case records “A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime.” The more relevant preventive control is “Review automation against supported SR Linux data models and reject unmanaged host-file configuration workflows,” because it follows the recorded cause rather than a different operational problem.

B:

The safeguard “Exercise least-privilege read-versus-write API tests in service-account reviews” is directed at another failure. This case records “A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime.” The more relevant preventive control is “Review automation against supported SR Linux data models and reject unmanaged host-file configuration workflows,” because it follows the recorded cause rather than a different operational problem.

C:

The safeguard “Require service-to-device dependency audits before approving fabric-wide change windows” is directed at another failure. This case records “A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime.” The more relevant preventive control is “Review automation against supported SR Linux data models and reject unmanaged host-file configuration workflows,” because it follows the recorded cause rather than a different operational problem.

Question 69

At Fictional BriarHorizon Energy, during post-maintenance resilience review in the east fabric pod, the SR Linux fabric team records the following exact evidence: A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime. Which underlying technical issue BEST explains the observed result?

  1. For the post-maintenance resilience review in the east fabric pod at Fictional BriarHorizon Energy, the runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state.
  2. For the post-maintenance resilience review in the east fabric pod at Fictional BriarHorizon Energy, the deployment plan copied a platform-independent port map without checking the actual hardware-specific interface inventory and capabilities.
  3. For the post-maintenance resilience review in the east fabric pod at Fictional BriarHorizon Energy, the automation identity has monitoring privileges but not the authorized configuration role needed for write operations.
  4. For the post-maintenance resilience review in the east fabric pod at Fictional BriarHorizon Energy, configuration and service dependencies are tracked in disconnected local notes rather than a mapped fabric service inventory.

Explanation

Correct Answer

A:

The Fictional BriarHorizon Energy case records: A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime. The directly supported underlying mechanism is: The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state. The relevant Nokia data center fabric design principle is: SR Linux exposes device configuration and operational state through structured models rather than unsupported file edits. The scoped correction is: Apply supported SR Linux CLI or model-based API operations to the appropriate configuration datastore and commit the change. Confirm the outcome by checking: The modeled configuration shows the intended route instance after commit and operational verification reflects the change.

Incorrect Answers

B:

This diagnosis alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A data center standard assumes that a 7220 IXR and a 7250 IXR have interchangeable physical port layouts during a staged cabling swap. That other situation is caused by: The deployment plan copied a platform-independent port map without checking the actual hardware-specific interface inventory and capabilities. The actual Fictional BriarHorizon Energy case instead says: A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime. Therefore the relevant diagnosis decision here is: The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state. The proposed alternative does not directly address or establish that specific outcome.

C:

This alternative concerns “The automation identity has monitoring privileges but not the authorized configuration role needed for write operations.” The recorded evidence is “A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime.” For this root-cause diagnosis, the more directly supported distinction is “The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state”; the alternative does not explain the stated condition.

D:

This alternative concerns “Configuration and service dependencies are tracked in disconnected local notes rather than a mapped fabric service inventory.” The recorded evidence is “A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime.” For this root-cause diagnosis, the more directly supported distinction is “The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state”; the alternative does not explain the stated condition.

Question 70

At Fictional BriarHorizon Energy, during post-maintenance resilience review in the east fabric pod, the SR Linux fabric team records the following exact evidence: A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime. Which scoped engineering response BEST addresses the underlying problem?

  1. For the post-maintenance resilience review in the east fabric pod at Fictional BriarHorizon Energy, validate the target model, port numbering, supported speeds and transceiver constraints before applying the port migration plan.
  2. For the post-maintenance resilience review in the east fabric pod at Fictional BriarHorizon Energy, apply supported SR Linux CLI or model-based API operations to the appropriate configuration datastore and commit the change.
  3. For the post-maintenance resilience review in the east fabric pod at Fictional BriarHorizon Energy, grant only the narrow permitted configuration role to the controller identity and apply requests to the proper datastore.
  4. For the post-maintenance resilience review in the east fabric pod at Fictional BriarHorizon Energy, associate tenant services and attachment points with managed fabric nodes and use dependency-aware maintenance planning.

Explanation

Correct Answer

B:

For the Fictional BriarHorizon Energy post-maintenance resilience review in the east fabric pod, the evidence is: A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime. The causal technical issue is: The runbook bypasses SR Linux model-driven configuration semantics and treats managed network state as arbitrary host filesystem state. The focused corrective engineering response is: Apply supported SR Linux CLI or model-based API operations to the appropriate configuration datastore and commit the change. The governing engineering principle is: SR Linux exposes device configuration and operational state through structured models rather than unsupported file edits. The acceptance check is: The modeled configuration shows the intended route instance after commit and operational verification reflects the change.

Incorrect Answers

A:

This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A data center standard assumes that a 7220 IXR and a 7250 IXR have interchangeable physical port layouts during a staged cabling swap. That other situation is caused by: The deployment plan copied a platform-independent port map without checking the actual hardware-specific interface inventory and capabilities. The actual Fictional BriarHorizon Energy case instead says: A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime. Therefore the relevant correction decision here is: Apply supported SR Linux CLI or model-based API operations to the appropriate configuration datastore and commit the change. The proposed alternative does not directly address or establish that specific outcome.

C:

“Grant only the narrow permitted configuration role to the controller identity and apply requests to the proper datastore” addresses a different corrective need. The documented situation is “A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime.” The better-matched targeted correction is “Apply supported SR Linux CLI or model-based API operations to the appropriate configuration datastore and commit the change,” because it deals with the specific problem described rather than an adjacent issue.

D:

“Associate tenant services and attachment points with managed fabric nodes and use dependency-aware maintenance planning” addresses a different corrective need. The documented situation is “A switch runbook recommends editing a Linux application file to alter an SR Linux routing instance, but the device rejects the change at runtime.” The better-matched targeted correction is “Apply supported SR Linux CLI or model-based API operations to the appropriate configuration datastore and commit the change,” because it deals with the specific problem described rather than an adjacent issue.

Nokia Data Center Fabric Fundamentals (4A0-D01) Practice Tests