Question 80
At Fictional BriarJunction Retail, during post-maintenance resilience review in the east fabric pod, the SR Linux fabric team records the following exact evidence: A data center standard assumes that a 7220 IXR and a 7250 IXR have interchangeable physical port layouts during a staged cabling swap. Which recurring operational safeguard BEST reduces the chance of the same failure happening again?
Explanation
Correct Answer
For Fictional BriarJunction Retail, the exact reported evidence is: A data center standard assumes that a 7220 IXR and a 7250 IXR have interchangeable physical port layouts during a staged cabling swap. The technical mechanism is: The deployment plan copied a platform-independent port map without checking the actual hardware-specific interface inventory and capabilities. The recurrence-prevention control most closely connected to this root problem is: Maintain a platform-specific BOM, interface map and optics qualification test for every switch model. This complements the immediate repair: Validate the target model, port numbering, supported speeds and transceiver constraints before applying the port migration plan. It is justified by the design rule: Common network OS behavior does not remove device-specific hardware interface and optics constraints. Confirm the repair via: The live port inventory matches the approved cabling map and all intended interfaces negotiate supported operational parameters.
Incorrect Answers
This prevention alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: An external fabric automation program tries to automate by parsing interactive screen prompts and fails when CLI presentation changes. That other situation is caused by: The application relies on unstable human-oriented output instead of the documented structured SR Linux interface. The actual Fictional BriarJunction Retail case instead says: A data center standard assumes that a 7220 IXR and a 7250 IXR have interchangeable physical port layouts during a staged cabling swap. Therefore the relevant prevention decision here is: Maintain a platform-specific BOM, interface map and optics qualification test for every switch model. The proposed alternative does not directly address or establish that specific outcome.
This prevention alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A new fabric deployment has correct leaf and spine cabling but its inventory service reports no relationships between devices. That other situation is caused by: The operational inventory lacks reconciled physical topology, node identity and intended endpoint relationships. The actual Fictional BriarJunction Retail case instead says: A data center standard assumes that a 7220 IXR and a 7250 IXR have interchangeable physical port layouts during a staged cabling swap. Therefore the relevant prevention decision here is: Maintain a platform-specific BOM, interface map and optics qualification test for every switch model. The proposed alternative does not directly address or establish that specific outcome.
This prevention alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: Fabric Services System reports a deployment as successful, but a new tenant workload still uses an older service profile. That other situation is caused by: The manager pushed intended fabric configuration without reconciling a stale tenant service assignment and its effective state. The actual Fictional BriarJunction Retail case instead says: A data center standard assumes that a 7220 IXR and a 7250 IXR have interchangeable physical port layouts during a staged cabling swap. Therefore the relevant prevention decision here is: Maintain a platform-specific BOM, interface map and optics qualification test for every switch model. The proposed alternative does not directly address or establish that specific outcome.