Question 710
At Fictional RidgeHorizon Energy, during post-maintenance resilience review in the east fabric pod, the SR Linux fabric team records the following exact evidence: A replacement node’s ZTP procedure runs only halfway; device logs show an artifact checksum mismatch after an image transfer. Which scoped engineering response BEST addresses the underlying problem?
Explanation
Correct Answer
For the Fictional RidgeHorizon Energy post-maintenance resilience review in the east fabric pod, the evidence is: A replacement node’s ZTP procedure runs only halfway; device logs show an artifact checksum mismatch after an image transfer. The causal technical issue is: The bootstrap server delivers a corrupted, truncated or wrong-version artifact that fails integrity validation. The focused corrective engineering response is: Publish a verified supported artifact and checksum, then repeat the provisioning download safely. The governing engineering principle is: ZTP artifacts must match expected content and platform/software compatibility before being applied. The acceptance check is: The artifact passes hash validation and the node completes the intended bootstrap without manual file substitution.
Incorrect Answers
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A new device downloads a configuration successfully but fails to bring up the planned underlay after its ZTP script completes. That other situation is caused by: The bootstrap references wrong site-specific port or routing variables for the switch model and location. The actual Fictional RidgeHorizon Energy case instead says: A replacement node’s ZTP procedure runs only halfway; device logs show an artifact checksum mismatch after an image transfer. Therefore the relevant correction decision here is: Publish a verified supported artifact and checksum, then repeat the provisioning download safely. The proposed alternative does not directly address or establish that specific outcome.
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A shared local administrator account makes it impossible to distinguish two operators who changed a tenant network instance. That other situation is caused by: Operators use an unaccountable common identity rather than individually attributable role-controlled logins. The actual Fictional RidgeHorizon Energy case instead says: A replacement node’s ZTP procedure runs only halfway; device logs show an artifact checksum mismatch after an image transfer. Therefore the relevant correction decision here is: Publish a verified supported artifact and checksum, then repeat the provisioning download safely. The proposed alternative does not directly address or establish that specific outcome.
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A gNMI client cannot establish a TLS connection after a server certificate renewal; the certificate name no longer matches the target hostname. That other situation is caused by: The TLS server identity does not validate against the name used by the monitoring client. The actual Fictional RidgeHorizon Energy case instead says: A replacement node’s ZTP procedure runs only halfway; device logs show an artifact checksum mismatch after an image transfer. Therefore the relevant correction decision here is: Publish a verified supported artifact and checksum, then repeat the provisioning download safely. The proposed alternative does not directly address or establish that specific outcome.