Question 730
At Fictional StoneCanyon Health, during pre-production tenant onboarding in the west fabric pod, the SR Linux fabric team records the following exact evidence: Fabric automation sends commands immediately after an alarm without a policy check and unintentionally blocks a production tenant. Which scoped engineering response BEST addresses the underlying problem?
Explanation
Correct Answer
The causal technical issue is: The EDA workflow acts on raw event triggers without validated scope, permissions or safety guardrails. The focused corrective engineering response is: Use a policy-controlled intent workflow with preconditions, constrained targets and a reversible change plan. The governing engineering principle is: Automated response must apply approved state transitions with safeguards, not blindly translate every alarm into a write. The acceptance check is: A synthetic alarm that violates policy produces no device change while an approved scenario follows its intended action.
Incorrect Answers
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: Two independent automation workflows alternate the same fabric setting and generate constant drift alerts. That other situation is caused by: The workflows have conflicting desired-state ownership for a single managed resource. Therefore the relevant correction decision here is: Use a policy-controlled intent workflow with preconditions, constrained targets and a reversible change plan. The proposed alternative does not directly address or establish that specific outcome.
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: The Kubernetes workload for an EDA reconciler restarts during a fabric deployment and the change remains partially applied. That other situation is caused by: The controller does not resume a durable reconciliation after an interrupted pod lifecycle. Therefore the relevant correction decision here is: Use a policy-controlled intent workflow with preconditions, constrained targets and a reversible change plan. The proposed alternative does not directly address or establish that specific outcome.
“Correct the declarative node membership and reconcile the intended topology against observed fabric links” addresses a different corrective need. The documented situation is “Fabric automation sends commands immediately after an alarm without a policy check and unintentionally blocks a production tenant.” The better-matched targeted correction is “Use a policy-controlled intent workflow with preconditions, constrained targets and a reversible change plan,” because it deals with the specific problem described rather than an adjacent issue.