Question 760
At Fictional StoneJunction Retail, during post-maintenance resilience review in the east fabric pod, the SR Linux fabric team records the following exact evidence: The Kubernetes workload for an EDA reconciler restarts during a fabric deployment and the change remains partially applied. Which recurring operational safeguard BEST reduces the chance of the same failure happening again?
Explanation
Correct Answer
For Fictional StoneJunction Retail, the exact reported evidence is: The Kubernetes workload for an EDA reconciler restarts during a fabric deployment and the change remains partially applied. The technical mechanism is: The controller does not resume a durable reconciliation after an interrupted pod lifecycle. The recurrence-prevention control most closely connected to this root problem is: Exercise pod-restart and recovery tests during EDA acceptance. This complements the immediate repair: Recover the controller and reconcile the declared fabric intent from persisted state rather than manually replaying uncertain commands. It is justified by the design rule: Kubernetes controller operations should tolerate restart and converge from declared desired state. Confirm the repair via: The reconciler resumes safely and the fabric matches intended state without duplicated or orphaned resources.
Incorrect Answers
This prevention alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A service-intent reconciler cannot read the Kubernetes secrets or service configuration it needs although its pod is running. That other situation is caused by: The Kubernetes service account lacks narrowly required access to its intended resources. The actual Fictional StoneJunction Retail case instead says: The Kubernetes workload for an EDA reconciler restarts during a fabric deployment and the change remains partially applied. Therefore the relevant prevention decision here is: Exercise pod-restart and recovery tests during EDA acceptance. The proposed alternative does not directly address or establish that specific outcome.
This prevention alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: An automated tenant service intent creates a VXLAN network for one tenant but also adds an unauthorized second tenant to its route-target set. That other situation is caused by: The service-intent definition contains an overbroad tenant membership or route-target mapping. The actual Fictional StoneJunction Retail case instead says: The Kubernetes workload for an EDA reconciler restarts during a fabric deployment and the change remains partially applied. Therefore the relevant prevention decision here is: Exercise pod-restart and recovery tests during EDA acceptance. The proposed alternative does not directly address or establish that specific outcome.
This prevention alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A reactive EDA alert continues to indicate an outage after the underlying interface recovers and operational state is normal. That other situation is caused by: The event-handling pipeline misses a recovery transition or does not reconcile the alarm with observed state. The actual Fictional StoneJunction Retail case instead says: The Kubernetes workload for an EDA reconciler restarts during a fabric deployment and the change remains partially applied. Therefore the relevant prevention decision here is: Exercise pod-restart and recovery tests during EDA acceptance. The proposed alternative does not directly address or establish that specific outcome.