Question 790
At Fictional WillowHorizon Energy, during post-maintenance resilience review in the east fabric pod, the SR Linux fabric team records the following exact evidence: The EDA observability dashboard reports every switch healthy even though a leaf BGP session is down and traffic is impaired. Which scoped engineering response BEST addresses the underlying problem?
Explanation
Correct Answer
For the Fictional WillowHorizon Energy post-maintenance resilience review in the east fabric pod, the evidence is: The EDA observability dashboard reports every switch healthy even though a leaf BGP session is down and traffic is impaired. The causal technical issue is: The health model aggregates node reachability but omits relevant protocol and forwarding-state telemetry. The focused corrective engineering response is: Extend the observability model with peer state, installed routes and affected service reachability indicators. The governing engineering principle is: Network observability needs service-relevant operational signals rather than a single device-up metric. The acceptance check is: A controlled BGP failure causes the intended fabric service and adjacency health alerts.
Incorrect Answers
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: A reactive EDA alert continues to indicate an outage after the underlying interface recovers and operational state is normal. That other situation is caused by: The event-handling pipeline misses a recovery transition or does not reconcile the alarm with observed state. The actual Fictional WillowHorizon Energy case instead says: The EDA observability dashboard reports every switch healthy even though a leaf BGP session is down and traffic is impaired. Therefore the relevant correction decision here is: Extend the observability model with peer state, installed routes and affected service reachability indicators. The proposed alternative does not directly address or establish that specific outcome.
This correction alternative pertains to a DISTINCT technical situation in the same official course module. Its distinguishing evidence is: Fabric automation sends commands immediately after an alarm without a policy check and unintentionally blocks a production tenant. That other situation is caused by: The EDA workflow acts on raw event triggers without validated scope, permissions or safety guardrails. The actual Fictional WillowHorizon Energy case instead says: The EDA observability dashboard reports every switch healthy even though a leaf BGP session is down and traffic is impaired. Therefore the relevant correction decision here is: Extend the observability model with peer state, installed routes and affected service reachability indicators. The proposed alternative does not directly address or establish that specific outcome.
“Upgrade or adapt the controller to the supported Kubernetes resource schema and validate the intent object against it” addresses a different corrective need. The documented situation is “The EDA observability dashboard reports every switch healthy even though a leaf BGP session is down and traffic is impaired.” The better-matched targeted correction is “Extend the observability model with peer state, installed routes and affected service reachability indicators,” because it deals with the specific problem described rather than an adjacent issue.